de los Santos, M. J. et al. ESHRE standard group on good practice in IVF laboratories. Hum. Reprod. 31, 1–30 (2015).
Ombelet, W., Cooke, I., Dyer, S., Serour, G. & Devroey, P. Infertility and the arrangement of infertility medical services in establishing nations. Hum. Reprod. Update 14, 605–621 (2008).
Kadi, S. & Wiesing, U. The German IVF Register as an instrument to record assisted reproductive innovations. Geburtshilfe und Frauenheilkunde 76, 680–684 (2019).
Glujovsky, D., Farquhar, C., Quinteiro Retamar, A. M., Alvarez Sedo, C. R. & Blake, D. Cleavage phase versus blastocyst phase embryo transfer in assisted reproductive innovation. Cochrane Database Syst. Rev. 30, CD002118 (2016).
Fordham, D. E. et al. Embryologist contract when evaluating blastocyst implantation possibility: is data-driven forecast the option to embryo evaluation subjectivity? Hum. Reprod. 37, 2275–2290 (2022).
De Croo, I., Van der Elst, J., Everaert, K., De Sutter, P. & Dhont, M. Fertilization, pregnancy and embryo implantation rates after ICSI with fresh or frozen-thawed testicular spermatozoa. Hum. Reprod. 13, 1893–1897 (1998).
Bashiri, A., Halper, K. I. & Orvieto, R. Recurrent implantation failure-update summary on etiology, medical diagnosis, treatment and future instructions. Reprod. Biol. Endocrinol. 16, 1–18 (2018).
Cimadomo, D., Craciunas, L., Vermeulen, N., Vomstein, K. & Toth, B. Definition, diagnostic and healing alternatives in frequent implantation failure: a global study of clinicians and embryologists. Hum. Reprod. 36, 305–317 (2021).
Cohen, J. The effectiveness and effectiveness of IVF and present. Hum. Reprod. 6, 613–618 (1991).
Simon, A. & Laufer, N. Assessment and treatment of duplicated implantation failure (RIF). J. Assist. Reprod. Genet. 29, 1227–1239 (2012).
Weissman, A. et al. Zygote intrafallopian transfer amongst clients with duplicated implantation failure. Int. J. Gynecol. Obstet. 120, 70–73 (2013).
Busnelli, A., Somigliana, E., Cirillo, F., Baggiani, A. & Levi-Setti, P. E. Efficacy of treatments and interventions for duplicated embryo implantation failure: a methodical evaluation and meta-analysis. Sci. Rep. 11, 1747 (2021).
Tournaye, H. et al. Tubal transfer: a forgotten ART? Hum. Reprod. 11, 1987–1990 (1996).
Ruiz-Alonso, M. et al. The endometrial receptivity selection for medical diagnosis and customized embryo transfer as a treatment for clients with duplicated implantation failure. Fertil. Steril. 100, 818–824 (2013).
Eytan, O., Elad, D., Zaretsky, U. & Jaffa, A. J. A glimpse into the uterus throughout in vitro simulation on embryo transfer. Hum. Reprod. 19, 562–569 (2004).
Medina-Sánchez, M. et al. Medical microbots require much better imaging and control. Nature 545, 406–408 (2017).
Schwarz, L. et al. A turning spiral micromotor for noninvasive zygote transfer. Adv. Sci. 7, 2000843 (2020).
Rivkin, B. et al. Electronically incorporated microcatheters based upon self-assembling polymer movies. Sci. Adv. 7, eabl5408 (2021).
Matsuda, T. & Kawahara, D. Electrospinning fabrication of high-trackable catheter pointer with slowly graded or gradient versatility. J. Biomed. Mater. Res. Part B Appl. Biomater. 87, 35–41 (2008).
Jeon, S. et al. A magnetically regulated soft microrobot guiding a guidewire in a three-dimensional phantom vascular network. Soft Robot. 6, 54–68 (2019).
Piskarev, Y. et al. A variable tightness magnetic catheter made from a conductive phase-change polymer for minimally intrusive surgical treatment. Adv. Funct. Mater. 32, 2107662 (2022).
Mattmann, M. et al. Thermoset shape memory polymer variable tightness 4D robotic catheters. Adv. Sci. 9, 2103277 (2022).
Misra, S., Reed, K. B., Schafer, B. W., Ramesh, K. T. & Okamura, A. M. Mechanics of versatile needles robotically guided through soft tissue. Int. J. Rob. Res. 29, 1640–1660 (2010).
Goudu, S. R. et al. Biodegradable untethered magnetic hydrogel milli-grippers. Adv. Funct. Mater. 30, 2004975 (2020).
Breger, J. C. et al. Self-folding thermo-magnetically responsive soft microgrippers. A/C Appl. Mater. Interfaces 7, 3398–3405 (2015).
Rajabasadi, F., Schwarz, L., Medina-Sánchez, M. & Schmidt, O. G. 3D and 4D lithography of untethered microrobots. Prog. Mater. Sci. 120, 100808 (2021).
Rajabasadi, F. et al. Multifunctional 4D-printed sperm-hybrid microcarriers for assisted recreation. Adv. Mater. 34, 2204257 (2022).
Aziz, A., Holthof, J., Meyer, S., Schmidt, O. G. & Medina-Sánchez, M. Dual ultrasound and photoacoustic tracking of magnetically driven micromotors: from in vitro to in vivo. Adv. Healthc. Mater. 10, 2101077 (2021).
Simerly, C. R. et al. Assisted reproductive innovations (ART) with baboons create live offspring: a nonhuman primate design for ART and reproductive sciences. Reprod. Sci. 17, 917–930 (2010).
Kadiri, V. M. et al. Light- and magnetically activated FePt microswimmers. Eur. Phys. J. E 44, 74 (2021).
FDA. Biological examination of medical gadgets. www.fda.gov/regulatory-information/search-fda-guidance-documents/%0Ause-international-standard-iso-10993-1-biological-evaluation-medical-devices-part-1-evaluation-and%0A (2016).
Ceylan, H. et al. 3D-printed naturally degradable microswimmer for theranostic freight shipment and release. A/C Nano 13, 3353–3362 (2019).
Giltinan, J., Sridhar, V., Bozuyuk, U., Sheehan, D. & Sitti, M. 3D microprinting of iron platinum nanoparticle‐based magnetic mobile microrobots. Adv. Intell. Syst. 3, 2000204 (2021).
Jessel, N. et al. Bioactive finishings based upon a polyelectrolyte multilayer architecture functionalized by ingrained proteins. Adv. Mater. 24, 33–41 (2003).
Qiu, F. et al. Magnetic helical microswimmers functionalized with lipoplexes for targeted gene shipment. Adv. Funct. Mater. 25, 1666–1671 (2015).
Wu, Z. et al. A microrobotic system directed by photoacoustic computed tomography for targeted navigation in intestinal tracts in vivo. Sci. Robot. 4, eaax0613 (2019).
Yasa, I. C., Ceylan, H., Bozuyuk, U., Wild, A. M. & Sitti, M. Elucidating the interaction characteristics in between microswimmer body and body immune system for medical microrobots. Sci. Robot. 5, eaaz3867 (2020).
Zhang, H., Li, Z., Wu, Z. & He, Q. Cancer cell membrane-camouflaged micromotor. Adv. Ther. 2, 1900096 (2019).
Cabanach, P. et al. Zwitterionic 3D‐printed non‐immunogenic stealth microrobots. Adv. Mater. 32, 2003013 (2020).
Wu, Z. et al. A swarm of slippery micropropellers permeates the vitreous body of the eye. Sci. Adv. 4, eaat4388 (2018).
Venugopalan, P. L., Jain, S., Shivashankar, S. & Ghosh, A. Single finishing of zinc ferrite renders magnetic nanomotors healing and steady versus heap. Nanoscale 10, 2327–2332 (2018).
Medina-Sánchez, M., Magdanz, V., Guix, M., Fomin, V. M. & Schmidt, O. G. Swimming microrobots: soft, reconfigurable, and wise. Adv. Funct. Mater. 28, 1707228 (2018).
Tipnis, N. P. & Burgess, D. J. Sterilization of implantable polymer-based medical gadgets: An evaluation. Int. J. Pharm. 544, 455–460 (2018).
Xu, H. et al. Sperm-hybrid micromotor for targeted drug shipment. A/C Nano 12, 327–337 (2018).
Medina-Sánchez, M., Schwarz, L., Meyer, A. K., Hebenstreit, F. & Schmidt, O. G. Cellular freight shipment: towards helped fertilization by sperm-carrying micromotors. Nano Lett. 16, 555–561 (2016).
Xu, H., Medina-Sánchez, M., Maitz, M. F., Werner, C. & Schmidt, O. G. Sperm micromotors for freight shipment through streaming blood. A/C Nano 14, 2982–2993 (2020).
Diemer, J., Hahn, J., Goldenbogen, B., Müller, K. & Klipp, E. Sperm migration in the genital system-In silico experiments determine crucial elements for reproductive success. PLoS Comput. Biol. 17, 1–17 (2021).
Herman, I. P. in Physics of the Human Body Ch. 7 (Springer, 2016).
Aziz, A. et al. Medical imaging of microrobots: towards in vivo applications. A/C Nano 14, 10865–10893 (2020).
Aziz, A., Medina-Sánchez, M., Claussen, J. & Schmidt, O. G. Real-time optoacoustic tracking of single moving micro-objects in deep phantom and ex vivo tissues. Nano Lett. 19, 6612–6620 (2019).
Emanuel, A. L. et al. Contrast-boosted ultrasound for metrology of tissue perfusion in people. Microcirculation 27, e12588 (2020).
Shi, C. et al. Application of a sub-0.1-mm3 implantable mote for in vivo real-time cordless temperature level noticing. Sci. Adv. 7, eabf6312 (2021).
Jabehdar Maralani, P. et al. Canadian association of radiologists suggestions for the safe usage of MRI throughout pregnancy. Can. Assoc. Radiol. J. 73, 56–67 (2022).
Trop, I., Tremblay, E., Thérasse, E. & Thomassin-Naggara, I. Quality efforts: standards for usage of medical imaging throughout pregnancy and lactation. Radiographics 32, 897–911 (2012).
Nelson, B. J., Kaliakatsos, I. K. & Abbott, J. J. Microrobots for minimally intrusive medication. Annu. Rev. Biomed. Eng. 12, 55–85 (2010).
Hwang, J., Kim, J. & Choi, H. An evaluation of magnetic actuation systems and magnetically activated guidewire- and catheter-based microrobots for vascular interventions. Intell. Serv. Robot. 13, 1–14 (2020).
Li, J., Mayorga-Martinez, C. C., Ohl, C. D. & Pumera, M. Ultrasonically moved micro- and nanorobots. Adv. Funct. Mater. 32, 2102265 (2021).
Luo, T. & Wu, M. Biologically influenced micro-robotic swimmers from another location managed by ultrasound waves. Lab Chip 21, 4095–4103 (2021).
Wells, P. N. T. Absorption and dispersion of ultrasound in biological tissue. Ultrasound Med. Biol. 1, 369–376 (1975).
Karstensen, L., Behr, T., Pusch, T. P., Mathis-Ullrich, F. & Stallkamp, J. Autonomous guidewire navigation in a 2 dimensional vascular phantom. Curr. Dir. Biomed. Eng. 6, 20200007 (2020).
European Medicines Agency. Predictions for medical gadget advancement. (2021).
Canady, R. FDA and nanotechnology for medical items. (2010).
Heads of Medicines Agencies (HMA) and European Medicines Agency. Guidance for candidates on a pilot for Simultaneous National Scientific Advice (SNSA). (2020).
Xu, H. et al. Sperm-hybrid micromotor for targeted drug shipment. A/C Nano 12, 327–337 (2018).
Xu, H. et al. Human spermbots for patient-representative 3D ovarian cancer cell treatment. Nanoscale 12, 20467–20481 (2020).